10.4-inch 6-parameter Patient Monitor
Item No.:CLD-9000 C
10.4-inch 6-parameter Patient Monitor
Inquiry Now
Manufacturer Specifications:
Features:   
  • Standard parameter: ECG, RESP, NIBP, SpO2, TEMP, PR. 
  • 10.4" large-screen color TFT display
  • Built-in high-capacity battery, up to 4 hours working time
  • 7-lead ECG waveforms display, big fonts observational interface
  • Reviewable ECG waveforms, Maximum 240 hours reviewing graphic trends
  • Digital SpO2 technique, precise measurement for weak perfusion and finger shaking
  • Arrhythmia and S-T segment analysis and pacemaker detection
  • Protection against interference from defibrillation and electrosurgical Unit
  • Applicable to ICU, CCU, operation, adult, pediatrics and neonatal patient
Standard configuration:            
  • ECG, NIBP, SPO2, TEMP, RESP, PULSE, Built-in rechargeable battery
Optional:            
  • Thermal printer, Dual TEMP, Single/Dual IBP, EtCO2
Specification:
 
 
ECG
Full lead: I, II, III, AVL, AVR, AVF and V
Gain: 5mm/mV, 10mm/mV, 15mm/mV, 20mm/mV and 25mm/mV
Scanning speed: Changeable with three grades of 12.5mm/s, 25mm/s and 50mm/s
Band width: 0.05Hz-100Hz(3dB)
Heart rate: 
Scope: 15 times/minute to 300 times/minutes
Accuracy:  ±1 time/minute
Variation of heart beat LORENZE drawing: Analysis on heart beat data for the current 5 minutes with histogram during RR period. 
Arrhythmia: Twenty kinds of common abnormal ECG can be analyzed, with ECG data of 1000 times of arrhythmia kept and with 10 seconds kept for each time.   
Accuracy: Error rate < 20%         
Undetected rate < 20% 
Analysis function should be started when using the above two kinds of function.
ST section 
Scope:     ±0.8mV
Precision :  < ±0.05mV
SpO2
Detection scope:   0%-100%
Accuracy         ±1%     90%-100%               
                 ±2%      70%-89% 
NIBP 
Theory Electric oscillator 
Cuff gassing time   less than 15 seconds
First-time gassing pressure: dynamic state 24kPa(180 mmHg)
Manual selection: 9.3kPa(70 mmHg),13.3kPa(100 mmHg),16.0kPa(120 mmHg)
18.6kPa(140 mmHg),20.0kPa(150 mmHg),21.3kPa(160 mmHg),
Automatic detection period: 1 minute to 240 minutes 
Stop size:1 min(1 min -10min), 5min(10 min -30min), 10min(30 m
in -90min) and 30min(90 min -240min)
Detection scope: 
Systolic blood pressure:   4kPa -34kPa(30mmHg -255mmHg)
Diastolic pressure             2kPa -29.3kPa(15mmHg -220mmHg)
Mean pressure               2.7kPa~31.3kPa       (20mmHg~235mmHg)
Detection accuracy 
Static pressure: ±3mmHg
Pulse rate:  ±2%
Resp
Chest impedance method or concentration of carbon dioxide at end o
f respiration 
Scope of chest impedance method     0 time/minute – 100 minutes/minute 
Precision of chest impedance method  time/minute 
Detection scope of carbon oxygen at end of respiration 3mmHg-75mmHg; 0.4%vol-9.9%vol
Detection scope of respiration rate: 2 times/minute ->60 times/minute(including baby)
Detection precision of respiration rate: ±1 time/minute 
Temp
Single/double path 
Type:    Vascular/surface temperature 
Scope:    20~50℃
Accuracy:  ±0.2
Invasive blood pressure (optional)
Single/double path 
Type: direct and continuous detection 
Scope: -6.67kPa(-50mmHg)—46.67kPa(350mmHg)
Precision: below 13.33kPa(100mmHg) ±0.27kPa(2mmHg)  13.33k
Pa(100mmHg) above ±2%
Frequency response:DC-12Hz
Input resistance: not less than 500kΩ
Sensitivity of sensor: 5μV/V/mmHg
Motivation voltage:5V (DC)
Accuracy of sensor: ±2%Isolation voltage: 4 kV