Digital 6-channel Electrocardiograph
Item No.:EKG-1206
Digital 6-channel Electrocardiograph
Manufacturer Specifications:
Features:
- Portable, compact, flexible and convenient to use
- Can measure, display and record standard 12-lead ECG waveforms.
- 6 channel with measurement report
- 5.6-inch single-color LCD: high light and high definition
- can display electrocardiogram wave and rhythm of heart and catch record opportunity
- Built-in rechargeable Ni-MH battery. Non-memory rechargeable battery to ensure continuous use of the device
- Chinese/English language.
- Measuring storage and review functions. Automatically saves records when user finishes printing every time. Each record has a maximum time of 50 seconds.
- Against high frequency electrosurgical generator equipment and defibrillation-proof
- Record means: automatic channel connecting means, manual channel
- Connecting means; 6-lead, 3+1-lead, 3-lead electrocardiogram, long time rhythm channel connecting record and periodical record.
- Real time record: record waves for 10s according to channel connecting
- 50/63/110/210mm recorder, can record 3-lead and 6-lead electrocardiogram.
- Web recording paper is more convenient
- Can be used to the physiological measure for adult, child and neonate.
Screen:
|
Size |
Catercorner 5.6 inches
|
|
Type Single Color
|
LCD
|
|
Resolution Ration
|
320*240
|
Control:
|
Criterion |
4 direction keys (F1-F4), Power supply switch key, Storage key, Print Start/Stop key.
|
EKG:
|
Usable standard leads |
Ⅰ,Ⅱ,Ⅲ, V1, V2, V3, V4, V5, V6, Avr, Avl and Avf
|
|
Lead fail
|
Identify the failed lead.
|
|
Alarm
|
No alarm
|
|
Input Impedance:
|
≥25MΩ
|
|
Voltage Range:
|
±300Mv
|
|
Common mode rejection ratio
|
≥90Db
|
|
Frequency Response:
|
0.05Hz-150Hz
|
|
Standard Precision:
|
10mm /1Mv±2%
|
Paper Recorder:
|
Method: |
Dot matrix
|
|
Level Resolution Ration:
|
40 d/mm, speed 25mm/s
|
|
Uprightness Resolution Ration:
|
8 d/mm
|
|
Wave Channels:
|
3/6
|
|
Paper Width:
|
110mm(4.33inches)
|
|
Paper Length:
|
15m(50inches)
|
|
Formfeed Speed:
|
5, 10, 12.5, 25 and 50mm/s(±2%)
|
Environment Instructions:
|
Power Supply Requirement: |
AC:120V~240V 50Hz/60Hz
|
|
Battery:
|
NI-MH, 12V, 1.8AH(model:205305)
|
|
Fuse:
|
2.0A, F2L 250V
|
|
Design(Routine):
|
Continuous operation, non-ingress of liquids Device.
|
|
Battery life:
|
When in ECG monitoring, the normal working time are 3 hours for fully charged battery.( Battery aging will reduce the using time)
|
|
Battery charged for more than 90%charging time:
|
6 ~ 12 hours
|
|
Operation Conditions:
Surrounding Temperatures: Relevant humidity: Atmospheric Pressure: |
10 ~ 40℃
25~95%(No Condensation) 700 ~ 1060hPa |
|
Restore Conditions:
Surrounding Temperature: Relevant humidity: Atmospheric Pressure: |
-20℃~55℃
≤93% 500hPa ~1060hPa |
Previous:
Next:




View larger image
Bookmark this product
Add to My Favorites