Fetal Monitor
Item No.:CLD-300C
Fetal Monitor
Inquiry Now
Manufacturer Specifications:
Features:         
  • Folded 12.1-inch TFT LCD high-brightness screen with a wide viewing angle and large numerics
  • 12 elements / 1 MHz water proof pulse Doppler transducer for accurate detection
  • Event marker for easy documentation of events and kick counts
  • Fetal Movement Profile (FMP) detects and automatically records gross fetal body movements
  • On-screen scrolling for viewing stored fetal traces
  • Twin ultrasound monitoring capability
  • Configurable audible and flashing fetal heart rate alarms
  • Twin signal overlap alarm function
  • Built-in high speed thermal printer, printing width can be set to 112mm,150mm and 210mm
  • 24-hours memory for fetal traces
  • Supporting TCP/IP or wireless connection to the central monitoring station
  • Internal Li-ion battery power or AC power from external power supply
 

Physical Specifications

 
Dimension and Weight
Dimension
35cm (W)*30cm (D)*11cm (H)
Weight
standard configuration: 4 kg
Operation Environment
Power requirements
AC100-240V , 50/60Hz
Power
100VA
Temperature
5-40
Humidity
30-93% non-condensing
Performance Specifications
Performance Specifications
Display
12.1inch (800X600 pixel) color TFT –LCD
Indicator
Visual on-display and integrated, alarm light, audible alarm
Battery
Internal rechargeable Li-ion battery power
Alarm
Visual on-display and integrated, alarm light, audible alarm
Memory
24-hours memory for fetal traces
Printer
America standard/international standard  
Built-in thermal printer (110mm, 150mm, 210mm for option)
1/2/3cm/min real-time printing speed, fast print speed (stored traces)
Paper
Z-fold, thermosensitive
Record Message
ID, name, age, date, time, print speed etc
CMS
Support connecting to central monitoring station through LAN (TCP/IP) or wireless connection
Technical Specifications
Ultrasound (FHR)
Measurement range
US
50 to 240 bpm
Resolution
Display
1bpm
Printer
1bpm
jitter@200 bpm
≤3bpm
Display update rate
0.25second
Beat to bea change(max.) for ultrasound
28bpm
US frequency
1MHz±5%Hz
TOCO
Measurement method
Strain gauge sensor element
Sensitivity 
1 unit =2.5g
Resolution
1 unit
Measurement range
500 units
Baseline setting
0, 5,10, 15, 20 can be selective
Update rate
0.25 second
Auto offset correction
3 second after connecting the transducer
Auto zero adjust 
 
TOCO value is set to zero negative following a negative
Measure value for 5 seconds
Auto Fetal Movement (AFM)
Technique
Pulsed doppler ultrasound
Range   
0-100%
Resolution
1%
Automatic fetal movement actograph
Manual fetal movement mark
NIBP
Operation mode
Manual/automatic/ STAT
Measurement unit
mmHg / kPa selectable
Test interval
0-480 minutes
Accuracy
Max.Std.deviation:8 mmHg(1.1kPa)
Max. mean Error: ±5mmHg(±0.7kPa)
Measurement range
Systolic
30 to 270 mmHg(4 to 36 kPa)
Diastolic
10 to 245 mmHg(1.5 to 32kPa)
Mean
20 to 255 mmHg(2.5 to 34kPa)
Pulse rate range
40~240bpm
Over-pressure protection
Yes
Maternal ECG (MECG)
Heart rate range
30~300bpm
Resolution
1bpm
Accuracy
±1bpm/ ±1%
Leads
I, II, III, avL, avR, avF, V
Sweep speed
12.5mm/s, 25mm/s, 50mm/s
Gain selection
x 0.25, x0.5 ,x1,1, x2
Operation mode
diagnostic, monitor, surgery
Maternal SpO2 (MSpO2)
Measurement range
0%-100%
Resolution
1%
Accuracy
±2%
Pulse rate range accuracy
±3bpm
Temperature (TEMP)
Technique
Thermistor probe CYSI 400 series compatible
Measurement range
0℃-50℃
Accuracy
±0.1