Maternal/Fetal Monitor
Item No.:CLD-8000
Maternal/Fetal Monitor
Inquiry Now
Manufacturer Specifications:
Features:            
  • 8.4 inch super resolution color TFT display
  • Maximum 9 waveforms
  • Use built-in system, high integrated intelligent module technology, full digital monitoring, super functions, lowest * swearing and low failure rate
  • Combined functions of maternal monitor and fetal monitor
  • Measure the intrapartum patient and fetal heart rate
  • Uterine contraction and fetal movement marker
  • Continuous real time recording of fetal heart rate
  • Can be switched to normal patient monitoring interface
  • 72 hours graphic trends and tabular of all parameters
  • 1440 groups of NIBP data storage
  • ST analysis
  • Anti-high frequency electronic surgical unit and anti-defibrillation, for monitoring in the surgery or for cardiac care
  • Use wide-angle, multi-wafer, wide beam and ultrasonic probes
Standard configuration:            
  • FHR, Uterine Contraction Pressure(TOCO), FM and Maternal ECG, NIBP, SPO2,  PULSE, thermal printer

Technical Specifications:

 
Safety
IEC60601 approved (GB9706)
Power source
AC100V-240V, 50/60Hz
Size
330mm(L) × 275mm(W) × 160mm(H)
Net weight
5.0 kg
Working
Temperature: 5 ~ 40
Humidity <= 85%
Transportation and Storage
Temperature: -20 ~ 55
Humidity <= 85%
Ultrasonic Probe: (Fetal Heart Rate)
Type
Type B proof, dirctional, using pulse doppler system
Working frequency
2.5 MHz
Transmitting power density
1.2m W/cm2
Probe
Multi-wafer probe
Sample rate
5 ms
Calculating precision of FHR
0.25 bpm
Accuracy of FHR
1 bpm (100-180 bpm)
Marker (Fetal Movement)
Manually push button mode
When pressed, a red strip will be displayed above the FHR graph
Uterine Contraction Pressure
Type B proof
Uterine contraction pressure probe
Manual zero adjustment
Design pressure sensitivity: 0-100%
ECG
Lead
5 leads (R, L, F, N, C)
Lead selection
I, II, III, avR, avL, avF, V
Waveform
7 channels
Gain selection
×0. 5, ×1, ×2
HR and alarm range
Adult: 15-300bpm
Neonate/pediatrics: 15-350bpm
Accuracy
±2% or ±2bpm, whichever is greater
Input impedance
> 5ΜΩ
Voltage range of electrode polarization
±300mV
Leakage current
< 30uA
Filter
Diagnostic mode: 0.05 ~ 100Hz
Monitoring mode: 0.5 ~ 35Hz
Surgical mode: 1 ~ 25Hz
Scaling signal
1mV ± 3%
Measurement range
-1.0mV ~ +1.0mV
Alarm Range
-0.80mV~0.80mV
RESP
Model
RA-LL impedance
Measurement range
Adult: 0 ~ 120bpm
Neonate/pediatrics: 1 ~ 150bpm
Resolution
1rpm
Accuracy
±2rpm
NIBP
Method
Automatic oscillometric
Operation mode
Auto/Manual
Alarm Type
Systolic, Diastolic, Mean
Measurement ranges
Systolic BP: 40 ~ 300mmHg
Diastolic BP: 10 ~ 220mmHg
Mean BP: 20 ~ 240mmHg
Resolution
1mmHg
Accuracy
Max average error ±5mmHg or ±5%, whichever is greater
Overload Protection
Double safety protection
 SPO2
Measurement Range
0 ~ 100%
Alarm range
0 ~ 100%
Resolution
1%
Accuracy
±2% (80~100%)
±3% (60~79%)
 PULSE RATE
Range
0 ~ 254bpm
Resolution
1bpm
Accuracy
±1bpm or ±2%, whichever is greater
Alarm delay time
10sec
 TEMP
Channel
2 channels
Measurement range
0~50
Alarm range
0~45
Resolution
0.1℃
Accuracy
±0.2